    [senki@fatengelyes-pc ~]$ sudo smartctl -a /dev/sdb
    smartctl 6.6 2017-11-05 r4594 [x86_64-linux-4.19.8-arch1-1-ARCH] (local build)
    Copyright (C) 2002-17, Bruce Allen, Christian Franke, www.smartmontools.org

    === START OF INFORMATION SECTION ===
    Model Family: Indilinx Barefoot based SSDs
    Device Model: Corsair CSSD-V32GB2
    Serial Number: 10340061080009870002
    Firmware Version: 2.1
    User Capacity: 32.017.047.552 bytes [32,0 GB]
    Sector Size: 512 bytes logical/physical
    Rotation Rate: Solid State Device
    Device is: In smartctl database [for details use: -P show]
    ATA Version is: ATA8-ACS (minor revision not indicated)
    Local Time is: Sun Dec 16 19:43:03 2018 CET
    SMART support is: Available - device has SMART capability.
    SMART support is: Enabled

    === START OF READ SMART DATA SECTION ===
    SMART Status not supported: Incomplete response, ATA output registers missing
    SMART overall-health self-assessment test result: PASSED
    Warning: This result is based on an Attribute check.

    General SMART Values:
    Offline data collection status: (0x00) Offline data collection activity
    was never started.
    Auto Offline Data Collection: Disabled.
    Self-test execution status: ( 0) The previous self-test routine completed
    without error or no self-test has ever
    been run.
    Total time to complete Offline
    data collection: ( 0) seconds.
    Offline data collection
    capabilities: (0x1d) SMART execute Offline immediate.
    No Auto Offline data collection support.
    Abort Offline collection upon new
    command.
    Offline surface scan supported.
    Self-test supported.
    No Conveyance Self-test supported.
    No Selective Self-test supported.
    SMART capabilities: (0x0003) Saves SMART data before entering
    power-saving mode.
    Supports SMART auto save timer.
    Error logging capability: (0x00) Error logging NOT supported.
    General Purpose Logging supported.
    Short self-test routine
    recommended polling time: ( 0) minutes.
    Extended self-test routine
    recommended polling time: ( 0) minutes.

    SMART Attributes Data Structure revision number: 16
    Vendor Specific SMART Attributes with Thresholds:
    ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
    1 Raw_Read_Error_Rate 0x0000 --- --- --- Old_age Offline - 6
    9 Power_On_Hours 0x0000 --- --- --- Old_age Offline - 489
    12 Power_Cycle_Count 0x0000 --- --- --- Old_age Offline - 807
    184 Initial_Bad_Block_Count 0x0000 --- --- --- Old_age Offline - 11
    195 Program_Failure_Blk_Ct 0x0000 --- --- --- Old_age Offline - 0
    196 Erase_Failure_Blk_Ct 0x0000 --- --- --- Old_age Offline - 0
    197 Read_Failure_Blk_Ct 0x0000 --- --- --- Old_age Offline - 0
    198 Read_Sectors_Tot_Ct 0x0000 --- --- --- Old_age Offline - 4239304818
    199 Write_Sectors_Tot_Ct 0x0000 --- --- --- Old_age Offline - 2197665990
    200 Read_Commands_Tot_Ct 0x0000 --- --- --- Old_age Offline - 90343929
    201 Write_Commands_Tot_Ct 0x0000 --- --- --- Old_age Offline - 38610438
    202 Error_Bits_Flash_Tot_Ct 0x0000 --- --- --- Old_age Offline - 11514836
    203 Corr_Read_Errors_Tot_Ct 0x0000 --- --- --- Old_age Offline - 10661622
    204 Bad_Block_Full_Flag 0x0000 --- --- --- Old_age Offline - 0
    205 Max_PE_Count_Spec 0x0000 --- --- --- Old_age Offline - 5000
    206 Min_Erase_Count 0x0000 --- --- --- Old_age Offline - 533
    207 Max_Erase_Count 0x0000 --- --- --- Old_age Offline - 1156
    208 Average_Erase_Count 0x0000 --- --- --- Old_age Offline - 898
    209 Remaining_Lifetime_Perc 0x0000 --- --- --- Old_age Offline - 83
    211 SATA_Error_Ct_CRC 0x0000 --- --- --- Old_age Offline - 0
    212 SATA_Error_Ct_Handshake 0x0000 --- --- --- Old_age Offline - 0
    213 Indilinx_Internal 0x0000 --- --- --- Old_age Offline - 0

    Warning! SMART ATA Error Log Structure error: invalid SMART checksum.
    SMART Error Log Version: 1
    No Errors Logged

    Warning! SMART Self-Test Log Structure error: invalid SMART checksum.
    SMART Self-test log structure revision number 1
    No self-tests have been logged. [To run self-tests, use: smartctl -t]

    Selective Self-tests/Logging not supported

    [senki@fatengelyes-pc ~]$

  • csixy

    addikt

    válasz ubyegon2 #64273 üzenetére

    :R Köszönöm az avanzsáltatást! :B

    Anyyira huncutul lett a telepítés, hogy a benti winnyóz a kingstonon UEFI-s , az USB-re meg legacyban MBR-re lett teleptve az arch. :DDD