Új hozzászólás Aktív témák

  • Crvsh3R

    senior tag

    válasz ubyegon2 #88904 üzenetére

    Köszi az észrevételeke! Overprovisioning nincs beállítva (a másolás pillanatában 100+GB szabad hely volt rajta), ez egy 1TB-os meghajtó, WD Red SA500 NAS SATA SSD M.2 2280.

    A kimenete a parancsnak:

    smartctl 7.2 2020-12-30 r5155 [aarch64-linux-6.1.19-v8+] (local build)
    Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org

    === START OF INFORMATION SECTION ===
    Model Family:     WD Blue / Red / Green SSDs
    Device Model:     WDC  WDS100T1R0B-68A4Z0
    Serial Number:    XXX
    LU WWN Device Id: 5 001b44 8b128ad43
    Firmware Version: 411000WR
    User Capacity:    1,000,204,886,016 bytes [1.00 TB]
    Sector Size:      512 bytes logical/physical
    Rotation Rate:    Solid State Device
    Form Factor:      M.2
    TRIM Command:     Available, deterministic, zeroed
    Device is:        In smartctl database [for details use: -P show]
    ATA Version is:   ACS-4 T13/BSR INCITS 529 revision 5
    SATA Version is:  SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
    Local Time is:    Sun Mar 26 10:29:32 2023 CEST
    SMART support is: Available - device has SMART capability.
    SMART support is: Enabled
    AAM feature is:   Unavailable
    APM level is:     254 (maximum performance)
    Rd look-ahead is: Enabled
    Write cache is:   Enabled
    DSN feature is:   Unavailable
    ATA Security is:  Disabled, NOT FROZEN [SEC1]
    Wt Cache Reorder: Unavailable

    === START OF READ SMART DATA SECTION ===
    SMART overall-health self-assessment test result: PASSED

    General SMART Values:
    Offline data collection status:  (0x00) Offline data collection activity
                                            was never started.
                                            Auto Offline Data Collection: Disabled.
    Self-test execution status:      (   0) The previous self-test routine completed
                                            without error or no self-test has ever
                                            been run.
    Total time to complete Offline
    data collection:                (    0) seconds.
    Offline data collection
    capabilities:                    (0x11) SMART execute Offline immediate.
                                            No Auto Offline data collection support.
                                            Suspend Offline collection upon new
                                            command.
                                            No Offline surface scan supported.
                                            Self-test supported.
                                            No Conveyance Self-test supported.
                                            No Selective Self-test supported.
    SMART capabilities:            (0x0003) Saves SMART data before entering
                                            power-saving mode.
                                            Supports SMART auto save timer.
    Error logging capability:        (0x01) Error logging supported.
                                            General Purpose Logging supported.
    Short self-test routine
    recommended polling time:        (   2) minutes.
    Extended self-test routine
    recommended polling time:        (  10) minutes.

    SMART Attributes Data Structure revision number: 4
    Vendor Specific SMART Attributes with Thresholds:
    ID# ATTRIBUTE_NAME          FLAGS    VALUE WORST THRESH FAIL RAW_VALUE
      5 Reallocated_Sector_Ct   -O--CK   100   100   ---    -    0
      9 Power_On_Hours          -O--CK   100   100   ---    -    12804
     12 Power_Cycle_Count       -O--CK   100   100   ---    -    337
    165 Block_Erase_Count       -O--CK   100   100   ---    -    53084803
    166 Minimum_PE_Cycles_TLC   -O--CK   100   100   ---    -    2
    167 Max_Bad_Blocks_per_Die  -O--CK   100   100   ---    -    180
    168 Maximum_PE_Cycles_TLC   -O--CK   100   100   ---    -    28
    169 Total_Bad_Blocks        -O--CK   100   100   ---    -    632
    170 Grown_Bad_Blocks        -O--CK   100   100   ---    -    0
    171 Program_Fail_Count      -O--CK   100   100   ---    -    0
    172 Erase_Fail_Count        -O--CK   100   100   ---    -    0
    173 Average_PE_Cycles_TLC   -O--CK   100   100   ---    -    9
    174 Unexpected_Power_Loss   -O--CK   100   100   ---    -    40
    184 End-to-End_Error        -O--CK   100   100   ---    -    0
    187 Reported_Uncorrect      -O--CK   100   100   ---    -    0
    188 Command_Timeout         -O--CK   100   100   ---    -    0
    194 Temperature_Celsius     -O---K   056   074   ---    -    44 (Min/Max 24/74)
    199 UDMA_CRC_Error_Count    -O--CK   100   100   ---    -    0
    230 Media_Wearout_Indicator -O--CK   001   001   ---    -    0x0062005a0062
    232 Available_Reservd_Space PO--CK   100   100   004    -    100
    233 NAND_GB_Written_TLC     -O--CK   100   100   ---    -    9604
    234 NAND_GB_Written_SLC     -O--CK   100   100   ---    -    10046
    241 Host_Writes_GiB         ----CK   253   253   ---    -    9703
    242 Host_Reads_GiB          ----CK   253   253   ---    -    334267
    244 Temp_Throttle_Status    -O--CK   000   100   ---    -    0
                                ||||||_ K auto-keep
                                |||||__ C event count
                                ||||___ R error rate
                                |||____ S speed/performance
                                ||_____ O updated online
                                |______ P prefailure warning

    General Purpose Log Directory Version 1
    SMART           Log Directory Version 1 [multi-sector log support]
    Address    Access  R/W   Size  Description
    0x00       GPL,SL  R/O      1  Log Directory
    0x01           SL  R/O      1  Summary SMART error log
    0x02           SL  R/O      2  Comprehensive SMART error log
    0x03       GPL     R/O      1  Ext. Comprehensive SMART error log
    0x04       GPL,SL  R/O      8  Device Statistics log
    0x06           SL  R/O      1  SMART self-test log
    0x07       GPL     R/O      1  Extended self-test log
    0x10       GPL     R/O      1  NCQ Command Error log
    0x11       GPL     R/O      1  SATA Phy Event Counters log
    0x24       GPL     R/O   1957  Current Device Internal Status Data log
    0x25       GPL     R/O   1957  Saved Device Internal Status Data log
    0x30       GPL,SL  R/O      9  IDENTIFY DEVICE data log
    0x80-0x9f  GPL,SL  R/W     16  Host vendor specific log
    0xde       GPL     VS       8  Device vendor specific log

    SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
    No Errors Logged

    SMART Extended Self-test Log Version: 1 (1 sectors)
    Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
    # 1  Short offline       Completed without error       00%     12668         -
    # 2  Short offline       Completed without error       00%      6915         -

    Selective Self-tests/Logging not supported

    SCT Commands not supported

    Device Statistics (GP Log 0x04)
    Page  Offset Size        Value Flags Description
    0x01  =====  =               =  ===  == General Statistics (rev 1) ==
    0x01  0x008  4             337  ---  Lifetime Power-On Resets
    0x01  0x010  4           12804  ---  Power-on Hours
    0x01  0x018  6     20348761502  ---  Logical Sectors Written
    0x01  0x020  6        31058800  ---  Number of Write Commands
    0x01  0x028  6    701009799064  ---  Logical Sectors Read
    0x01  0x030  6     82441973566  ---  Number of Read Commands
    0x07  =====  =               =  ===  == Solid State Device Statistics (rev 1) ==
    0x07  0x008  1               0  N--  Percentage Used Endurance Indicator
                                    |||_ C monitored condition met
                                    ||__ D supports DSN
                                    |___ N normalized value

    Pending Defects log (GP Log 0x0c) not supported

    SATA Phy Event Counters (GP Log 0x11)
    ID      Size     Value  Description
    0x0001  4            0  Command failed due to ICRC error
    0x0002  4            0  R_ERR response for data FIS
    0x0005  4            0  R_ERR response for non-data FIS
    0x000a  4            1  Device-to-host register FISes sent due to a COMRESET
    Néha le szoktam futtatni, rövid SMART teszt nem mutatott hibát. Elméletben 600TBW-s a meghajtó, annak még a közelében sincs.

Új hozzászólás Aktív témák